dc.description.abstract | The X-IFU instrument of the ATHENA mission requires a set of thermal filters to reduce the photon shot noise onto its cryogenic detector and to protect it from molecular contamination. A set of five filters, operating at different nominal temperatures corresponding to the cryostat shield temperatures, is currently baselined. The knowledge of the actual filter temperature profiles is crucial to have a good estimation of the radiative load on the detector. Furthermore, a few filters may need to be warmed-up to remove contaminants and it is necessary to ensure that a threshold temperature is reached throughout the filters surface. For these reasons, it is fundamental to develop a thermal modeling of the full set of filters in a representative configuration. The baseline filter is a polyimide membrane 45 nm thick coated with 30 nm of highpurity aluminum, mechanically supported by a metallic honeycomb mesh. In this paper, we describe the implemented thermal modeling and report the results obtained in different studies: (i) a trade-off analysis on how to reach a minimum target temperature throughout the outer filter, (ii) a thermal analysis when varying the emissivity of the filter surfaces, and (iii) the effect of removing one of the filters. | en_US |
dc.language.iso | eng | en_US |
dc.title | Thermal modelling of the ATHENA X-IFU filters | en_US |
dc.type | Conference paper | - |
dc.identifier.doi | 10.1117/12.2314453 | en_US |
dc.identifier.scopus | 2-s2.0-85051851431 | en_US |
dc.identifier.isi | 000452819200119 | en_US |
dc.identifier.url | https://www.spiedigitallibrary.org/conference-proceedings-of-spie/10699/2314453/Thermal-modelling-of-the-ATHENA-X-IFU-filters/10.1117/12.2314453.full | en_US |
dc.relation.medium | ELETTRONICO | en_US |
dc.relation.volume | 10699 | en_US |
dc.relation.firstpage | 1069950 | en_US |
dc.type.referee | REF_3 | en_US |
dc.description.note | Copyright 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. | en_US |
dc.relation.alleditors | den Herder, Jan-Willem A.; Nikzad, Shouleh; Nakazawa, Kazuhiro | en_US |
dc.relation.ispartofbook | Space Telescopes and Instrumentation 2018: Ultraviolet to Gamma Ray | en_US |
dc.relation.conferencename | Space Telescopes and Instrumentation 2018: Ultraviolet to Gamma Ray | en_US |
dc.relation.conferenceplace | Austin, Texas, United States | en_US |
dc.relation.conferencedate | 10-15 June, 2018 | en_US |
dc.relation.scientificsector | FIS/05 - ASTRONOMIA E ASTROFISICA | en_US |
dc.type.miur | 273 Contributo in Atti di convegno | - |
dc.relation.series | PROCEEDINGS OF SPIE | en_US |
dc.identifier.adsbibcode | 2018SPIE10699E..50S | en_US |
dc.relation.ercsector | Scienze Fisiche Settori ERC (ERC) di riferimento::PE9 Universe sciences: astro-physics/chemistry/biology; solar systems; stellar, galactic and extragalactic astronomy, planetary systems, cosmology, space science, instrumentation::PE9_17 Instrumentation – telescopes, detectors and techniques | en_US |
dc.description.apc | no | en_US |
dc.description.oa | 1 – prodotto con file in versione Open Access (allegare il file al passo 5-Carica) | en_US |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | Conference paper | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
item.fulltext | With Fulltext | - |
crisitem.author.dept | O.A. Palermo | - |
crisitem.author.dept | O.A. Palermo | - |
crisitem.author.dept | O.A. Palermo | - |
crisitem.author.dept | O.A. Palermo | - |
crisitem.author.orcid | 0000-0003-0318-3546 | - |
crisitem.author.orcid | 0000-0001-7834-5760 | - |
crisitem.author.orcid | 0000-0002-7114-4031 | - |
crisitem.author.orcid | 0000-0002-3188-7420 | - |
crisitem.journal.journalissn | 0277-786X | - |
crisitem.journal.ance | E136238 | - |
Appears in Collections: | 3.01 Contributi in Atti di convegno |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
2018 Sciortino - Thermal modelling of the ATHENA X-IFU filters.pdf | Pdf editoriale | 1.04 MB | Adobe PDF | View/Open |
Page view(s)
52
checked on Apr 18, 2024
Download(s)
41
checked on Apr 18, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are published in Open Access, unless otherwise indicated.