dc.contributor.author | STEFANI, STEFANIA | en_US |
dc.contributor.author | ZAMBELLI, MASSIMO | en_US |
dc.contributor.author | Fonti, Sergio | en_US |
dc.contributor.author | BOCCACCINI, Angelo | en_US |
dc.date.accessioned | 2023-02-08T14:47:31Z | - |
dc.date.available | 2023-02-08T14:47:31Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.12386/33290 | - |
dc.description.abstract | The scope of these tests is to study the performance and eventually to identify any possible degradation of the dichroic after the radiation tests. The sample has been exposed at a total electron dose of 100 krad in two steps. The electron dose has been obtained at the e-LINAC, a facility of the Azienda Ospedaliera di Terni” (AOT). The tests have been performed on May 17th 2015 and June 6th 2015. The optical performances of the dichroic has been measured by using a Fourier Transform InfraRed (FT-IR) spectrometer and a Perkin Elmer Lamda. The spectral transmittance and reflectance was obtained in the spectral range of interest from 0.3 to 8 μm. | en_US |
dc.language.iso | eng | en_US |
dc.title | OH Dichroic Radiation Test Report | en_US |
dc.type | Research report | - |
dc.relation.medium | ELETTRONICO | en_US |
dc.relation.volume | JUI-IAPS-MAJ-RP-009 | en_US |
dc.relation.numberofpages | 42 | en_US |
dc.type.referee | REF_0 | en_US |
dc.description.numberofauthors | 4 | en_US |
dc.description.international | no | en_US |
dc.contributor.country | ITA | en_US |
dc.relation.scientificsector | FIS/05 - ASTRONOMIA E ASTROFISICA | en_US |
dc.type.miur | 298 Altro | en_US |
dc.relation.versioning | 1 | en_US |
dc.contributor.approved | Filacchione, Gianrico; Piccioni, Giuseppe | en_US |
dc.description.oa | 2 – prodotto con deroga per i casi previsti dalla Policy (allegare il modulo al passo 5-Carica) | en_US |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.openairetype | Research report | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | embargo_20370131 | - |
item.fulltext | With Fulltext | - |
crisitem.author.dept | IAPS Roma | - |
crisitem.author.dept | IAPS Roma | - |
crisitem.author.dept | IAPS Roma | - |
crisitem.author.orcid | 0000-0001-5762-4947 | - |
crisitem.author.orcid | 0000-0003-4436-5784 | - |
crisitem.author.orcid | 0000-0003-4052-1137 | - |
È visualizzato nelle collezioni: | 4.03 Rapporti di progetto |
File in questo documento:
File | Descrizione | Dimensioni | Formato | Existing users please |
---|---|---|---|---|
JUI-IAPS-MAJ-RP-009-1.4_Dichroic_Radiation_Testing_compressed.pdf | 7.77 MB | Adobe PDF | Embargoed until 31 gennaio 2037 |
Page view(s)
42
controllato il 24-apr-2024
Download(s)
2
controllato il 24-apr-2024
Google ScholarTM
Check
Tutti i documenti in DSpace sono pubblicati ad Accesso Aperto, salvo diversa indicazione per alcuni documenti specifici.