Here we calculate the expected countrates and ToF distribution for the ELENA instrument. ELENA (Emitted Low-Energy Neutral Atoms) is a neutral sensor, part of the SERENA instrument package, for the ESA cornerstone BepiColombo mission to Mercury; it is a new kind of low energetic neutral atoms instrument. It is designed to measure the sputtering emission from planetary surface in the energy range from E ~50eV up to E~5 keV. ELENA is a Time-of-Flight (ToF) sensor, based on oscillating shutter (operated at frequencies up to a 100 kHz) and mechanical gratings. The incoming neutral particles directly impinge on the entrance with a definite timing (START) and arrive to a STOP detector at the end of a Time-of-Flight (ToF) chamber. This paper describes both the analytical and the numerical estimation of the expected countrates for the ELENA sensor. We consider ion sputtering, backscattering and charge-exchange as possible neutral sources. The instrument noise on the stop MCP is also considered.

ELENA estimated countrates

MURA, Alessandro;MILILLO, Anna;ORSINI, Stefano;
2012-01-01

Abstract

Here we calculate the expected countrates and ToF distribution for the ELENA instrument. ELENA (Emitted Low-Energy Neutral Atoms) is a neutral sensor, part of the SERENA instrument package, for the ESA cornerstone BepiColombo mission to Mercury; it is a new kind of low energetic neutral atoms instrument. It is designed to measure the sputtering emission from planetary surface in the energy range from E ~50eV up to E~5 keV. ELENA is a Time-of-Flight (ToF) sensor, based on oscillating shutter (operated at frequencies up to a 100 kHz) and mechanical gratings. The incoming neutral particles directly impinge on the entrance with a definite timing (START) and arrive to a STOP detector at the end of a Time-of-Flight (ToF) chamber. This paper describes both the analytical and the numerical estimation of the expected countrates for the ELENA sensor. We consider ion sputtering, backscattering and charge-exchange as possible neutral sources. The instrument noise on the stop MCP is also considered.
File in questo prodotto:
File Dimensione Formato  
DEL19_BC-SRN-EL_Counts_v1.1.pdf

non disponibili

Licenza: Non specificato
Dimensione 3.23 MB
Formato Adobe PDF
3.23 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12386/33331
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact