TV3 Test Report: DCU secondary voltage and FPGA temperature
Date Issued
2020
Author(s)
Dusini, Stefano
•
•
•
•
Borsato, Enrico
•
•
Davini, Stefano
•
Di Domizio, Sergio
•
Di Ferdinando, Donato
•
Giacomini, Francesco
•
•
•
•
Mauri, Nicoletta
•
•
Patrizii, Laura
•
Renzi, Alessandro
•
•
Sirri, Gabriele
•
Stanco, Luca
•
Tenti, Matteo
•
•
•
•
Valerio, Benedetta
•
Valieri, Claudia
•
Ventura, Sandro
•
Verza, Giovanni
Abstract
The document report the values of the SCE power supply, the DCU 5V power line and DCUs FPGA temperature measured during the NISP FM TV3. Two data set have been analysed: the first include all values measured during the entire TV3, the second restrict to the Wide Survey test in which NISP was executing the reference observation sequence as was defined at the time of TV3. For a detailed description of the TV3 test specifications and test setup we refer to AD1 and RD2.