The document report the power consumption on the primary power lines of the NI-DPU FM measured during the NISP FM Thermal/Vacuum #3 test, in short TV3, performed at Operating Temperature (OT) in the Erios vacuum chamber at LAM, Marseilles. We refer to RD2

TV3 Test Report: NI-DPU FM power consumption and thermal behaviour during NISP FM TV3 test

GIANOTTI, FULVIO;MEDINACELI VILLEGAS, Eduardo;MARONGIU, Pasqualino;TRIFOGLIO, MASSIMO;TOSI, Silvano;VALENZIANO, LUCA;AURICCHIO, NATALIA;BALESTRA, Andrea;BATTAGLIA, Paola Maria;BONINO, Donata;Capobianco, Vito;FARINELLI, Ruben;FRANCESCHI, ENRICO
2020-01-01

Abstract

The document report the power consumption on the primary power lines of the NI-DPU FM measured during the NISP FM Thermal/Vacuum #3 test, in short TV3, performed at Operating Temperature (OT) in the Erios vacuum chamber at LAM, Marseilles. We refer to RD2