The document report the power consumption on the primary power lines of the NI-ICU FM measured during the NISP FM Thermal/Vacuum #3 test, in short TV3, performed at Operating Temperature (OT) in the Erios vacuum chamber at LAM, Marseilles. We refer to RD2
TV3 Test Report: NI-ICU FM power consumption and thermal behaviour during NISP FM TV3 test
AURICCHIO, NATALIA;BALESTRA, Andrea;BATTAGLIA, Paola Maria;BONINO, Donata;Capobianco, Vito;CORCIONE, Leonardo;FARINELLI, Ruben;FRANCESCHI, ENRICO;GIANOTTI, FULVIO;LIGORI, Sebastiano;MEDINACELI VILLEGAS, Eduardo;TRIFOGLIO, MASSIMO;TOSI, Silvano;VALENZIANO, LUCA;
2020-01-01
Abstract
The document report the power consumption on the primary power lines of the NI-ICU FM measured during the NISP FM Thermal/Vacuum #3 test, in short TV3, performed at Operating Temperature (OT) in the Erios vacuum chamber at LAM, Marseilles. We refer to RD2File in questo prodotto:
| File | Dimensione | Formato | |
|---|---|---|---|
|
EUCL-INFN-TR-7-007_TV3_TR_ICU_power.pdf
non disponibili
Licenza:
Non specificato
Dimensione
516.43 kB
Formato
Adobe PDF
|
516.43 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |