The document report the power consumption on the primary power lines of the NI-ICU FM measured during the NISP FM Thermal/Vacuum #3 test, in short TV3, performed at Operating Temperature (OT) in the Erios vacuum chamber at LAM, Marseilles. We refer to RD2

TV3 Test Report: NI-ICU FM power consumption and thermal behaviour during NISP FM TV3 test

AURICCHIO, NATALIA;BALESTRA, Andrea;BATTAGLIA, Paola Maria;BONINO, Donata;Capobianco, Vito;CORCIONE, Leonardo;FARINELLI, Ruben;FRANCESCHI, ENRICO;GIANOTTI, FULVIO;LIGORI, Sebastiano;MEDINACELI VILLEGAS, Eduardo;TRIFOGLIO, MASSIMO;TOSI, Silvano;VALENZIANO, LUCA;
2020-01-01

Abstract

The document report the power consumption on the primary power lines of the NI-ICU FM measured during the NISP FM Thermal/Vacuum #3 test, in short TV3, performed at Operating Temperature (OT) in the Erios vacuum chamber at LAM, Marseilles. We refer to RD2
File in questo prodotto:
File Dimensione Formato  
EUCL-INFN-TR-7-007_TV3_TR_ICU_power.pdf

non disponibili

Licenza: Non specificato
Dimensione 516.43 kB
Formato Adobe PDF
516.43 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12386/34581