This document describes analysis of the Dark acquire during the NISP-FM third Thermal Balance (TB) and Thermal Vacuum (TV) test campaign. The test was conducted at LAM during January and February 2020.
NISP DARK measurement during TB/TV3
DURAS, Federica;FRANCESCHI, ENRICO;MEDINACELI VILLEGAS, Eduardo;TRIFOGLIO, MASSIMO;VALENZIANO, LUCA;
2020-01-01
Abstract
This document describes analysis of the Dark acquire during the NISP-FM third Thermal Balance (TB) and Thermal Vacuum (TV) test campaign. The test was conducted at LAM during January and February 2020.File in questo prodotto: