DE ANGELIS, SimoneSimoneDE ANGELISNovi, SamueleSamueleNovi2023-02-222023-02-222016http://hdl.handle.net/20.500.12386/33768This document reports on the Ma_Miss EQM SAC and NEW EQM FORJ preliminary spectral characterization. Tests have been performed coupling the AVANTES spectro-photometers with the output fiber of Ma_Miss GSE illumination system and EQM SAC + NEW FORJ, acquiring signal in two different configurations. In addition to absolute radiometric measurements performed with Si photodiode, measurements with a spectrometer are essential in order to characterize the spectral behavior of all instrument subsystems. Such measurements must be intended as preliminary, and more systematic spectral analyses should be planned in the next future.ELETTRONICOenMA_MISS GSE illumination system + EQM-SAC + NEW-EQM-FORJ – PRELIMINARY CHARACTERIZATION and SPECTRAL PERFORMANCES TESTSResearch reportFIS/05 - ASTRONOMIA E ASTROFISICA