Planck LFI – FM database Release Note
Date Issued
2008
Author(s)
Abstract
This document contains the release note for the LFI FM database version 4.4.2 based on the official release (LFI FM 4.3.2) with the following NCRs applied: NCR 14328 - Temperatures and currents validity, Currents OOL and Alphanumeric display layout; NCR 11635 - not possible to add monitoring on telemetry event 5.1, 5.2, 5.4; NCR LFI-0004 - Numerical calibration format; NCR LFI-0005 - Numerical calibration decimal separator; NCR LFI-0006 - CDF_INTER for uncalibrated values; NCR LFI-0007 - Wrong parameter used in TM(5,1); NCR LFI-0009 - Unreferenced parameters and empty graphical display; NCR LFI-0013 - Soft instead of hard OOL; NCR LFI-0014 - Redundant parameters in display LA009350; NCR LFI-0015 - FEM drain currents warm OOLs; NCR LFI-0016 - REBA internal temperatures; NCR LFI-0017 - DAE Fast Essential and REBA Essential packets; NCR LFI-0018 - Missing parameter in the DAE Actual configuration packet; NCR LFI-0019 - Missing nominal scientific packet uncompressed; NCR LFI-0020 - Alarm and warning declaration for event packets; NCR LFI-0021 - Missing Command Verification Stages for LFI telecommands;
Volume
PL-LFI-OAT-TN-043
Rights
open.access
File(s)![Thumbnail Image]()
Loading...
Name
PL-LFI-OAT-TN-043_v1.3_LFI_FM_MIB_4.4.2.pdf
Description
Planck LFI FM MIB 4.4.2
Size
166.94 KB
Format
Adobe PDF
Checksum (MD5)
8007426ad8dd4fc27e26302b812e6906