  4. 4.03 Rapporti di progetto
  5. Requirements for the cryogenics LNA and the DL-FLL for SAFARI SPICA
 

Requirements for the cryogenics LNA and the DL-FLL for SAFARI SPICA

Date Issued
2009
Author(s)
MACCULI, CLAUDIO  
•
PIRO, LUIGI  
•
Bastia, P.
•
Torrioli, G.
•
Colasanti, L.  
Abstract
This Note is aimed at specifying the requirements for both the cryogenic LNA and the DL-FLL system for the readout of the SAFARI instrument. The major issue of this work is the amplification chain, so the development of the cryogenic LNA. By means of this device it is also possible to implement a new model for the readout system of the SAFARI instrument, called DL-FLL, based on the FDM technique. The reference document for the SPICA-SAFARI amplification chain is RD1. The baseline readout configuration is based on the so-called BBFB proposed by SRON to read array of pixels (160 Pixels per 35 channels) by the FDM technique. The Italian consortium, which is developing the DL-FLL in the X-ray case, proposed this technique to the SAFARI-consortium as a study activity for backup solution. The concept of the DL-FLL it is shown in RD2.
Uri
http://hdl.handle.net/20.500.12386/33726
Rights
restricted
File(s)
Loading...
Thumbnail Image
Name

SPICA_IT_REQ.pdf

Description
[Administrators only]
Size

168.24 KB

Format

Adobe PDF

Checksum (MD5)

09d2126961393aa1a2e1c31359ee52ab

Explore By
  • Communities and Collection
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Information and guides for authors
  • https://openaccess-info.inaf.it: all about open access in INAF
  • How to enter a product: guides to OA@INAF
  • The INAF Policy on Open Access
  • Downloadable documents and templates

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback