Repository logo
  • English
  • Italiano
Log In
Have you forgotten your password?
  1. Home
  2. PRODOTTI RICERCA INAF
  3. 4 ALTRI PRODOTTI SCIENTIFICI (Other scientific products)
  4. 4.03 Rapporti di progetto
  5. Planck-LFI CPV: Functionality Reference Point
 

Planck-LFI CPV: Functionality Reference Point

Date Issued
2009
Author(s)
BATTAGLIA, Paola Maria  
•
Bersanelli, Marco
•
CUTTAIA, FRANCESCO  
•
Davis, Richard
•
Wilkinson, Althea
•
FRAILIS, Marco  
•
Franceschet, Cristian
•
FRANCESCHI, ENRICO  
•
GALEOTTA, Samuele  
•
GREGORIO, Anna
•
Leonardi, Rodrigo
•
Lowe, Stuart
•
Mandolesi, NAZZARENO  
•
MARIS, Michele  
•
Meinhold, Peter
•
Mendes, Luis
•
MENNELLA, ANIELLO  
•
Poutanen,Torsti
•
SANDRI, MAURA  
•
TAVAGNACCO, Daniele  
•
TERENZI, LUCA  
•
Tomasi, Maurizio
•
VILLA, Fabrizio  
•
ZACCHEI, Andrea  
•
Zonca, Andrea
Abstract
This document describes the results from the Functionality Reference Test (FRT) The FRT is composed of two parts, devoted to different tasks. The first part is identical to the CRYO 02: it is devoted to checking the functionality of radiometers in all the possible phase switch and 4KHz combinations, after the HYM Tuning (that was considered a possible source of stress for radiometers) and to compare with it. In particular, the LNAs drain currents will be compared, together with the noise properties as 1/f, white noise, spikes. The output voltage can be compared just roughly considering the sky signal, because the ref signal decreases due to 4K cooler cooldown: this rough comparison must take into account possible differences in the SCS temperature ( driving the FPU temperature and hence the LNAs gain) and the radiometers Isolation ( the signal leaking from the Reference loads and mixing with the Sky signal is proportional to the Reference Load temperature). The second part is identical to the same test performed in CSL (Liege , 2008), but is performed with the LNAs bias set to the final configuration outcome from the HYM Tuning. This test, similar from the procedural point of view to the CRYO 01, is devoted to setting a reference point for the future of the survey, characterizing one by one all the LNAs measuring both the scientific output and the bias ( drain currents). This is operation can be repeated at any time during the survey, with a minimum effect on other channels not under test.
Volume
PL-LFI-PST-RP-070
Uri
http://hdl.handle.net/20.500.12386/33263
Rights
open.access
File(s)
Loading...
Thumbnail Image
Name

PL-LFI-PST-RP-070-reference_test.pdf

Description
Planck-LFI CPV: Functionality Reference Point
Size

1.75 MB

Format

Adobe PDF

Checksum (MD5)

595484636c6baa39196cc20909123d82

Explore By
  • Communities and Collection
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Information and guides for authors
  • https://openaccess-info.inaf.it: all about open access in INAF
  • How to enter a product: guides to OA@INAF
  • The INAF Policy on Open Access
  • Downloadable documents and templates

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback