Analysis of drain current and isolations anomalies in radiometer LFI24S observed during TV-TB tests in CSL
Date Issued
2008
Author(s)
•
•
•
D'Arcangelo, Ocleto
•
Franceschet, Cristian
•
GREGORIO, Anna
•
Meinhold, Peter
•
•
Tomasi, Maurizio
Abstract
This document summarises the analysis of an anomalous behaviour observed with the radiometer LFI24-
S during the TV-TB tests in CSL.
This document has been issued in the frame of ASI contract that has been released for the activities of
Planck-LFI Phase E2
Volume
PL-LFI-PST-TN-087
Rights
open.access