Title: | Monte Carlo evaluation of a CZT 3D spectrometer suitable for a Hard X- and soft-γ rays polarimetry balloon borne experiment | Authors: | CAROLI, EZIO DE CESARE, GIOVANNI Curado da Silva, R. M. Abbene, L. AURICCHIO, NATALIA Budtz-Jorgensen, C. DEL SORDO, STEFANO Ferrando, P. Galvez, J. L. Hernanz, M. Isern, J. Kuvvetli, I. Laurent, P. Limousin, O. Maia, J. M. Moita, M. Produit, N. STEPHEN, JOHN BUCHAN Zappettini, A. |
Issue Date: | 2015 | Volume: | 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) | Series: | PROCEEDINGS..IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE | First Page: | 1 | Abstract: | Today, the measurement of the polarization status of cosmic sources high-energy emission, is recognized as a key observational parameter to understand the active production mechanism and its geometry. Therefore, a mandatory requirement for new instrumentations operating in this energy range will be to provide high sensitivity for polarimetric measurements. In this framework, we have presented the concept of a small high-performance imaging spectrometer optimized for polarimetry between 100 and 600 keV suitable for a stratospheric balloon-borne payload and as a pathfinder for a future satellite mission. The detector with 3D spatial resolution is based on a CZT spectrometer in a highly segmented configuration designed to operate simultaneously as a high performance scattering polarimeter. Herein, we report results of a Monte Carlo study devoted to optimize the configuration of the detector for polarimetry with particular focus on event selection filter able to increase the polarimetric performance. This preliminary analysis shows that a procedure to optimize the polarization response of a 3D spectrometers should first of all determine the best tradeoff between the statistical significance and the quality of the modulation factor. | Conference Name: | IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) | Conference Place: | San Diego, CA, USA | Conference Date: | 31 October - 7 November 2015 | URI: | http://hdl.handle.net/20.500.12386/23984 | URL: | https://ieeexplore.ieee.org/document/7582278 | ISBN: | 978-1-4673-9862-6 | DOI: | 10.1109/NSSMIC.2015.7582278 | Fulltext: | open |
Appears in Collections: | 3.01 Contributi in Atti di convegno |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Caroli_Montecarlo-evaluation-IEEE-NSS-Conf_PostP.pdf | postprint | 483.58 kB | Adobe PDF | View/Open |
Caroli-Montecarlo evaluation of a CZT 3D spectrometer-IEEE NSS Conf Rec.pdf | [administrators only] | 480.04 kB | Adobe PDF |
Page view(s)
64
checked on Dec 5, 2024
Download(s)
23
checked on Dec 5, 2024
Google ScholarTM
Check
Altmetric
Altmetric
Items in DSpace are published in Open Access, unless otherwise indicated.