Title: | BepiColombo MPO Electro Magnetic Compatibility (EMC) Conducted Emission (CE) Test at ESTEC 09/09/2015 – 11/09/2015 SERENA Instrument Summary Report | Authors: | Di Lellis, Andrea Maria Camozzi, Fabio ARONICA, Alessandro LAZZAROTTO, FRANCESCO |
Issue Date: | 2015 | Number: | BC-SRN-TN-04105 | Abstract: | This is the test report describing the measure collected by the SERENA PI egse, during the Electro Magnetic Compatibility (EMC) Conducted Emission (CE) Test in the test centre room (“Rosetta Clean Room”) at ESTEC, Noordwijk (NL). The objective of the Conducted EMC test is to demonstrate that BepiColombo is: Compliant with the BepiColombo satellite level requirements as per [RD3] BC-ASD-TS-00014 Issue 02 "MPO/MCS EMC Functional Verification Specification", Compatible with the conducted emission requirements, re-checking unit and instrument EMC behavior on spacecraft level , self-compatible with the conducted emission and susceptibility thresholds. | Note: | Issue: 1 , Revision: 0 , date: 23/09/2015 , Delivered to: ESA/ESTEC | URI: | http://hdl.handle.net/20.500.12386/24255 | Fulltext: | open |
Appears in Collections: | 4.03 Rapporti di progetto |