Utilizza questo identificativo per citare o creare un link a questo documento:
http://hdl.handle.net/20.500.12386/24690
Campo DC | Valore | Lingua |
---|---|---|
dc.contributor.author | MACCULI, CLAUDIO | en_US |
dc.contributor.author | ARGAN, ANDREA | en_US |
dc.contributor.author | D'ANDREA, MATTEO | en_US |
dc.contributor.author | LOTTI, Simone | en_US |
dc.contributor.author | PIRO, LUIGI | en_US |
dc.contributor.author | Biasotti, Michele | en_US |
dc.contributor.author | Corsini, Dario | en_US |
dc.contributor.author | Gatti, Flavio | en_US |
dc.contributor.author | Orlando, Angiola | en_US |
dc.contributor.author | Torrioli, Guido | en_US |
dc.date.accessioned | 2020-05-11T13:08:59Z | - |
dc.date.available | 2020-05-11T13:08:59Z | - |
dc.date.issued | 2016 | en_US |
dc.identifier.issn | 0022-2291 | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.12386/24690 | - |
dc.description.abstract | The ATHENA observatory is the second large-class ESA mission, in the context of the Cosmic Vision 2015-2025, scheduled to be launched on 2028 at L2 orbit. One of the two planned focal plane instruments is the X-ray Integral Field Unit (X-IFU), which will be able to perform simultaneous high-grade energy spectroscopy and imaging over the 5 arcmin FoV by means of a kilo-pixel array of transition-edge sensor (TES) microcalorimeters, coupled to a high-quality X-ray optics. The X-IFU sensitivity is degraded by the particle background, induced by primary protons of both solar and cosmic rays' origin and secondary electrons. A Cryogenic AntiCoincidence (CryoAC) TES-based detector, located <1 mm below the TES array, will allow the mission to reach the background level that enables its scientific goals. The CryoAC is a 4-pixel detector made of Silicon absorbers sensed by Iridium TESs. We currently achieve a TRL = 3-4 at the single-pixel level. We have designed and developed two further prototypes in order to reach TRL = 4. The design of the CryoAC has been also optimized using the Geant4 simulation tool. Here we will describe some results from the Geant4 simulations performed to optimize the design and preliminary test results from the first of the two detectors, 1 cm<SUP>2</SUP> area, made of 65 Ir TESs. | en_US |
dc.language.iso | eng | en_US |
dc.title | The Cryogenic AntiCoincidence Detector for the ATHENA X-IFU: Design Aspects by Geant4 Simulation and Preliminary Characterization of the New Single Pixel | en_US |
dc.type | Article | - |
dc.identifier.doi | 10.1007/s10909-015-1439-y | en_US |
dc.identifier.scopus | 2-s2.0-84952920118 | en_US |
dc.identifier.isi | 000379022700024 | en_US |
dc.identifier.url | https://link.springer.com/article/10.1007/s10909-015-1439-y | en_US |
dc.relation.medium | STAMPA | en_US |
dc.relation.volume | 184 | en_US |
dc.relation.issue | 3-4 | en_US |
dc.relation.firstpage | 680 | en_US |
dc.type.referee | REF_1 | en_US |
dc.relation.scientificsector | FIS/05 - ASTRONOMIA E ASTROFISICA | en_US |
dc.relation.journal | JOURNAL OF LOW TEMPERATURE PHYSICS | en_US |
dc.type.miur | 262 Articolo in rivista | - |
dc.identifier.adsbibcode | 2016JLTP..184..680M | en_US |
dc.description.apc | no | en_US |
dc.description.oa | 1 – prodotto con file in versione Open Access (allegare il file al passo 5-Carica) | en_US |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairetype | Article | - |
item.cerifentitytype | Publications | - |
crisitem.journal.journalissn | 0022-2291 | - |
crisitem.journal.ance | E092553 | - |
crisitem.author.dept | IAPS Roma | - |
crisitem.author.dept | Direzione Scientifica | - |
crisitem.author.dept | IAPS Roma | - |
crisitem.author.dept | IAPS Roma | - |
crisitem.author.dept | IAPS Roma | - |
crisitem.author.orcid | 0000-0002-7887-1485 | - |
crisitem.author.orcid | 0000-0002-6230-665X | - |
crisitem.author.orcid | 0000-0002-5139-4578 | - |
crisitem.author.orcid | 0000-0002-3088-1561 | - |
crisitem.author.orcid | 0000-0003-4159-3984 | - |
È visualizzato nelle collezioni: | 1.01 Articoli in rivista |
File in questo documento:
File | Descrizione | Dimensioni | Formato | |
---|---|---|---|---|
JLTP-D-15-00265_R2_draft.pdf | preprint | 3.23 MB | Adobe PDF | Visualizza/apri |
Macculi2016_Article_TheCryogenicAntiCoincidenceDet.pdf | [Administrators only] | 1.2 MB | Adobe PDF |
Page view(s)
115
controllato il 12-set-2024
Download(s)
222
controllato il 12-set-2024
Google ScholarTM
Check
Altmetric
Altmetric
Tutti i documenti in DSpace sono pubblicati ad Accesso Aperto, salvo diversa indicazione per alcuni documenti specifici.