  5. Twin-Shaping Filter Technique Applied to CZT Detectors
 

Twin-Shaping Filter Technique Applied to CZT Detectors

Date Issued
2017
Author(s)
AURICCHIO, NATALIA  
•
SCHIAVONE, FILOMENA  
•
CAROLI, EZIO  
•
BASILI, ANGELO  
•
STEPHEN, JOHN BUCHAN  
•
ZAPPETTINI, ANDREA
•
ZAMBELLI, NICOLA
•
BENASSI, GIACOMO
•
FATEMI, S.
•
PROTTI, NICOLETTA
•
SAVERIO, ALTIERI
DOI
10.1109/NSSMIC.2017.8533069
Abstract
CdTe/CdZnTe is an attractive and consolidated material with which to realize detectors with good efficiency and energy resolution, operating at room temperature for a large variety of applications such as astrophysics, medical imaging and security. However, this type of material suffers from the low mobility of the charge carriers (particularly the holes), which are trapped and so degrade the detector response in terms of charge collection efficiency, energy resolution and photopeak efficiency. The response of a planar CdTe/CdZnTe detector, which depends on the distance between the charge formation position and the collecting electrodes, can be improved by using two kinds of techniques, based on the optimization of the electrode geometry and/or signal compensation methods. We are studying the feasibility and the reliability of a biparametric method that uses a twin pulse shaping active filter to analyze each signal from the detector twice: one “Slow”, which is proportional to the energy of the incident photon, and one “Fast”, which depends on the position of the interaction with respect to the collecting electrode. In this paper we describe the bi-parametric technique applied to planar CdZnTe detectors grown by CNR/IMEM and to Spectrometer Grade detectors. We report the experimental results in terms of energy resolution, peak-to valley ratio and photopeak efficiency, as well as the compensated spectra obtained as a function of the bias voltage, photon energy and shaping time pairs. We also report the results obtained by using a CdZnTe drift strip detector. Furthermore, this technique could be implemented in an array of detectors, whose front-end electronics is composed of ASICs, where the shaping time can be selected for each channel, like the RENA-3 IC (NOVA R&D).
Coverage
2017 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
Start page
1
Conferenece
IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)
Conferenece place
Atlanta, GA, USA
Conferenece date
21-28 October, 2017
Uri
http://hdl.handle.net/20.500.12386/27118
Url
https://ieeexplore.ieee.org/document/8533069
Rights
open.access
File(s)
Loading...
Thumbnail Image
Name

Auricchio et al-Twin-Shaping Filter Technique for CZT sensors-IEEE Conf Rec-2017.pdf

Description
[Administrators only]
Size

1.98 MB

Format

Adobe PDF

Checksum (MD5)

ff5a20505c3687693c0fe34fa61ca267

Loading...
Thumbnail Image
Name

Auricchio et al-Twin-Shaping Filter Technique for CZT sensors-IEEE Conf Rec-2017-OA.pdf

Description
postprint
Size

2.11 MB

Format

Adobe PDF

Checksum (MD5)

d2d5ecc05040ff50350d69ab98bbe1fd

Explore By
  • Communities and Collection
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Information and guides for authors
  • https://openaccess-info.inaf.it: all about open access in INAF
  • How to enter a product: guides to OA@INAF
  • The INAF Policy on Open Access
  • Downloadable documents and templates

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback