  5. BepiColombo MPO PFM Radiated EMC tests at ESTEC 01/12/2015-09/12/2015 SERENA Instrument Summary Report
 

BepiColombo MPO PFM Radiated EMC tests at ESTEC 01/12/2015-09/12/2015 SERENA Instrument Summary Report

Date Issued
2016
Author(s)
ARONICA, Alessandro  
•
LAZZAROTTO, FRANCESCO  
•
Laky, Gunter
•
Svensson, Johan
•
Phillips, Mark
DOI
10.13140/RG.2.2.19069.31205
Abstract
This document provides a summary report on the testing activities named “Radiated EMC test” executed from the 1 st of December to the 9 th of December 2015 in the Rosetta clean room located at ESTEC, Noordwijk (NL), on the MPO with all payloads connected and fully operating. In particular the document describes activities and reports results of the tests performed on the SERENA FS suite as well as analyses data received from the instrument and collected by the SERENA PI-EGSE during the whole test session. Tests execution and management was mainly under the responsibility of TAS-I and ADS teams but supervised by ESA. P/L instrument teams staff was also required for verification purposes. All TM data packets, here generally analysed and discussed, were regularly stored in SERENA PI-EGSE. Moreover several screenshots and graphs showing the instrument behaviour and functionality were collected. During the Radiated EMC test SERENA worked in both emissive mode (MAXEMI) and susceptibility mode (MAXSUS). All planned tests run on the SERENA suite were performed as expected and successfully. So that the overall instrument behaviour can be considered nominal. All TM packets were received from each sub-system and for any category. Flux of HK and SCI data was regular, data quality as expected. Currents and Temperatures were nominal during the whole test session, except some little but nominal oscillations of MIPA TOF Board temperature and some random negligible spikes of ELENA Shutter temperature. All SERENA settings and thresholds were consistent to the default values. Some sets of OOL happened during the whole test session have not to be considered a concern. A remarkable event has to be mentioned: on the 8 th of December, after a reboot foreseen by the nominal procedure, STROFIO was unable to receive and execute TCs again. But power OFF of STROFIO and then power ON again allowed to recover the lost communication between STROFIO and SCU.
Volume
BC-SRN-TN-04108
Uri
http://hdl.handle.net/20.500.12386/27160
Rights
open.access
File(s)
Loading...
Thumbnail Image
Name

BC-SRN-TN-04108_1_0_SERENA_RAD_EMC_Test_Report_ESTEC_Dec2015.pdf

Description
Test Report
Size

4.06 MB

Format

Adobe PDF

Checksum (MD5)

1880b87626df9306635328a03c5c1e74

Explore By
  • Communities and Collection
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Information and guides for authors
  • https://openaccess-info.inaf.it: all about open access in INAF
  • How to enter a product: guides to OA@INAF
  • The INAF Policy on Open Access
  • Downloadable documents and templates

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback