The National Institute of Nuclear Physics (INFN) is supporting the 3CaTS project with the aim of developing a new Single Photon Emission Computed Tomography (SPECT) system for real time 10 B therapeutic dose monitoring in the binary experimental hadron therapy called Boron Neutron Capture Therapy (BNCT). BNCT is a highly selective tumour treatment based on the neutron capture reaction 10 B(n,α) 7 Li. The secondary particles have a high LET with ranges in tissues of the order of 10 μm (thus less than the mean cell diameter of few tens μm). Targeting the 10 B delivery towards cancer, the released energy lethally damages only the malignant cells sparing the normal tissues, thus enabling a cell-level selective treatment. To properly exploit this selectivity it is mandatory to know the 10 B spatial distribution inside patients body during neutron irradiation. This can be achieved by detecting the 478 keV γ ray emitted in the 94% of 10 B capture reactions by a SPECT system. A 3D CZT drift strip detector with a sensitive volume of 20x20x5 mm 3 was developed, able to perform high-resolution X-ray and γ ray spectroscopic imaging (10-1000 keV). The detector signals are analysed by a custom digital multi-channel electronics, based on two pipelined fast and slow analysis, able to perform multi-parameter analysis and fine temporal coincidences (<; 20 ns). Energy resolution of 3.3% (4 keV) and 2% (13 keV) FWHM was measured, with uncollimated sources and no corrections, at 122 keV and 662 keV, respectively.

High performance 3D CZT spectro-imager for BNCT-SPECT: preliminary characterization

AURICCHIO, NATALIA;CAROLI, EZIO;BASILI, ANGELO;
2018-01-01

Abstract

The National Institute of Nuclear Physics (INFN) is supporting the 3CaTS project with the aim of developing a new Single Photon Emission Computed Tomography (SPECT) system for real time 10 B therapeutic dose monitoring in the binary experimental hadron therapy called Boron Neutron Capture Therapy (BNCT). BNCT is a highly selective tumour treatment based on the neutron capture reaction 10 B(n,α) 7 Li. The secondary particles have a high LET with ranges in tissues of the order of 10 μm (thus less than the mean cell diameter of few tens μm). Targeting the 10 B delivery towards cancer, the released energy lethally damages only the malignant cells sparing the normal tissues, thus enabling a cell-level selective treatment. To properly exploit this selectivity it is mandatory to know the 10 B spatial distribution inside patients body during neutron irradiation. This can be achieved by detecting the 478 keV γ ray emitted in the 94% of 10 B capture reactions by a SPECT system. A 3D CZT drift strip detector with a sensitive volume of 20x20x5 mm 3 was developed, able to perform high-resolution X-ray and γ ray spectroscopic imaging (10-1000 keV). The detector signals are analysed by a custom digital multi-channel electronics, based on two pipelined fast and slow analysis, able to perform multi-parameter analysis and fine temporal coincidences (<; 20 ns). Energy resolution of 3.3% (4 keV) and 2% (13 keV) FWHM was measured, with uncollimated sources and no corrections, at 122 keV and 662 keV, respectively.
2018
978-1-5386-8494-8
978-1-5386-8495-5
File in questo prodotto:
File Dimensione Formato  
Fatemi-High performance 3D CZT-IEEE Conf Rec 2018free.pdf

accesso aperto

Licenza: Non specificato
Dimensione 817.53 kB
Formato Adobe PDF
817.53 kB Adobe PDF Visualizza/Apri
08824381.pdf

non disponibili

Licenza: Non specificato
Dimensione 1.32 MB
Formato Adobe PDF
1.32 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12386/30374
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact