BC-SIM-TN-014 SIMBIO-SYS_Compatibility_Rules
Date Issued
2022
Author(s)
•
•
Carlier, Vincent
•
•
•
•
Doressoundiram, Alain
•
•
•
Vincendon, Mathieu
Description
Si ringrazia ASI per aver reso possibile il progetto
Abstract
This document, in accordance with the Spectrometers and Imagers for MPO BepiColombo Integrated Observatory SYStem (SIMBIO-SYS) Technical Note, Layout and Data flow agreement detailed in [RD.1], reports all the interdependence rules between the parameters (i.e., PSSxxx) in a single SIMBIO-SYS TeleCommand (TC) to make it compatible with respect to the Main Electronics (ME) Application SoftWare ASWv2.7) and so being executable. These rules are fundamental in building correct Flight Operation procedures (FOPs) and all other higher-level commanding sequences as Payload Direct Operation Request (PDOR), Payload Operation Request (POR), Memory Operation Request (MOR) and Instrument TimeLine (ITL) that use FOPs with open (i.e., formal) parameters.
This is a sort of “living document” since present version describes two rules which are considered, for the time being, the most important ones:
1. Compatibility between commanded windows size and Compression settings of the Compression Unit (CU) in the ME
2. Definition of the lower limit of the Repetition Time (RT)
3. On-board processing for data refinement
Report number
214
Rights
open.access
File(s)![Thumbnail Image]()