Title: MAJIS Shutter QM and FM Thermo-vacuum Test Report
Authors: STEFANI, STEFANIA 
PICCIONI, GIUSEPPE 
BIONDI, David 
BOCCACCINI, Angelo 
Issue Date: 2023
Series: INAF Technical Reports - Rapporti Tecnici INAF 
Report: 240
Abstract: This test report provides a summary of the Thermo-Vacuum Test results on the QM and FM shutter units, a mechanical part of the spectrometer MAJIS (Moon And Jupiter Imaging Spectrometer), a payload instrument on board of the JUCE (JUpiter ICy moons Explorer) mission. The shutter actuator is composed by an electromagnetic brushless actuator mounted with an aluminium blade. The aims of the actuator are to maintain the blade in two stable positions (open and closed), to rotate the blade from one position to other in a time less than 300ms and a low power consumption. These tests have been conducted to demonstrate the capability of the shutter to operate according to requirements in vacuum at predefined temperature conditions. The target temperatures for the QM model are Top-Min = 100K and Top-Max = 165K and pressures less than 1 mbar. A total number of thermo-vacuum cycles of 42 are requested, including an extra hot point at 337K but only for the first cycle at the beginning. A slope of 2.7K/min has been agreed and planned for all the cycles. For the life test, performed only on the QM1, selected as reference, a total number of 1500 cycles at the same conditions of T and P are requested. For what concerns the test performed on the FM model, the target temperature is Top-Min = 105K and Top-Max = 160K. A total number of thermo-vacuum cycles of 4 are requested, including an extra hot point at 337K but only for the first cycle at the beginning. A slope of 2.7K/min has been agreed and planned for all the cycles.
URI: http://hdl.handle.net/20.500.12386/33107
https://doi.org/10.20371/INAF/TechRep/240
Fulltext: open
Appears in Collections:4.01 Rapporti tecnici INAF

Files in This Item:
File Description SizeFormat
ShutterMAJIS_rev.pdfReport2.42 MBAdobe PDFView/Open
Show full item record

Page view(s)

33
checked on Mar 26, 2023

Download(s)

7
checked on Mar 26, 2023

Google ScholarTM

Check


Items in DSpace are published in Open Access, unless otherwise indicated.


Explore by
  • Communities
    & Collections
  • Research outputs
  • Researchers
  • Organization units
  • Projects

Informazioni e guide per autori

https://openaccess-info.inaf.it: tutte le informazioni sull'accesso aperto in INAF

Come si inserisce un prodotto: le guide a OA@INAF

La Policy INAF sull'accesso aperto

Documenti e modelli scaricabili

Feedback
Built with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE