Title: | Planck-LFI CPV: Blanking Time Verification | Authors: | BATTAGLIA, Paola Maria Bersanelli, Marco CUTTAIA, FRANCESCO Davis, Richard FRAILIS, Marco Franceschet, Cristian FRANCESCHI, ENRICO GALEOTTA, Samuele GREGORIO, Anna Leonardi, Rodrigo Lowe, Stuart MARIS, Michele Meinhold, Peter Mendes, Luis MENNELLA, ANIELLO Poutanen,Torsti SANDRI, MAURA TAVAGNACCO, Daniele TERENZI, LUCA Tomasi, Maurizio VILLA, Fabrizio ZACCHEI, Andrea Zonca, Andrea |
Issue Date: | 2009 | Number: | PL-LFI-PST-RP-073 | Abstract: | This test consists in five steps, of about 15 minutes, with different blanking times: 7.5 µιχρο−s, 0 µιχρο−s, 15 µιχρο−s, 22.5 µιχρο−s, and again 7.5 µιχρο−s. In particular, we want to verify that: no current drops or abrupt variations are observed in FEM drain currents; no frequency spikes are observed besides those already characterised during the SPIKE-02 test; frequency spikes are not affected by the different blanking time values; no pop-corn noise is detected in radiometer voltage outputs. | Note: | Planck LFI Commissioning and Performance Verification (CPV) | URI: | http://hdl.handle.net/20.500.12386/33265 | Fulltext: | open |
Appears in Collections: | 4.03 Rapporti di progetto |