Utilizza questo identificativo per citare o creare un link a questo documento:
http://hdl.handle.net/20.500.12386/34564
Titolo: | Procedure to configure NISP Focal Plane for room temperature operations – SCA Zero Bias | Autori: | MEDINACELI VILLEGAS, Eduardo Zadeja, Anton Dusini, Stefano SIRIGNANO, CHIARA Castaldini, Enrico |
Data pubblicazione: | 2020 | Abstract: | The configuration of the NISP focal plane to operate at room temperature so-called SCA zero bias configuration was developed to operate the NISP focal plane with the DCUs powered ON and the SCEs fully bootstrapped but without activating the SCAs. In this way is assured that all the engineering operations of the NISP focal plane are allowed with the nominal timing and data production flux. Details about the procedure can be found in RD-1 (ITAR protected) and results of the validation tests can be found in RD-2 (ITAR protected). Here is descrived the procedure to apply the ZBC. | URI: | http://hdl.handle.net/20.500.12386/34564 | Fulltext: | reserved |
È visualizzato nelle collezioni: | 4.03 Rapporti di progetto |
File in questo documento:
File | Descrizione | Dimensioni | Formato | Existing users please |
---|---|---|---|---|
EUCL-IBO-TN-7-023-PublicSCAZeroBiasProcedure1.0.pdf | Administrators only | 1.3 MB | Adobe PDF |
Page view(s)
25
controllato il 15-mag-2024
Download(s)
3
controllato il 15-mag-2024
Google ScholarTM
Check
Tutti i documenti in DSpace sono pubblicati ad Accesso Aperto, salvo diversa indicazione per alcuni documenti specifici.