Abstract
In this technical note we propose a reconfiguration of the LFI on-board data processing and scientific telemetry following the new baseline design of the LFI instrument without the 100 GHz radiometer chains. The proposed strategy uses part of the telemetry resources liberated by the removal of the 100 GHz channel to download the total power radiometer data for all the channels, thus avoiding the on-board differencing between the sky and reference load data that was introduced to comply with the LFI telemetry budget. We show that the proposed new scheme is compatible with the available telemetry and can be implemented with minimal impact on the on-board and on-ground data processing. Furthermore it relaxes some criticalities in the DPC-MOC-satellite communication and improves the LFI instrument monitoring and systematic error control.