The Calibration Unit (CU) of MORFEO, the Multiconjugate adaptive Optics Relay For ELT Observations (formerly known as MAORY), is a complex optomechanical subsystem to project on the telescope NGS and LGS focal planes a large number of light sources at different wavelengths. These sources are needed to run calibration, verification and test procedures on MORFEO at the Extremely Large Telescope (ELT). This subsystem will play a critical role not only during operations, but also during the Assembly, Integration and Verification (AIV) phase in Italy, when it will be used in the Test Unit (TU) configuration, including a Deformable Mirror (DM), and in Chile. We present a general overview of the CU preliminary design, focusing on the reasons that led to the current optomechanical configuration and providing a more detailed description of the calibration sources, the light transmission chain and the electronics....

MAORY/MORFEO at ELT: calibration unit overview

DI RICO, Gianluca;DI ANTONIO, Ivan;Rodeghiero, Gabriele;VALENTINI, Angelo;DOLCI, Mauro;BUSONI, LORENZO;RIVA, Marco;FARINATO, JACOPO;CASCONE, Enrico;CHINELLATO, Simonetta;CIANNIELLO, Vincenzo;D'AURIA, Domenico;DE CAPRIO, VINCENZO;EREDIA, Christian;GIRO, Enrico;MAGRIN, DEMETRIO;PORTALURI, Elisa;REDAELLI, EDOARDO MARIA ALBERTO;SALASNICH, Bernardo;CILIEGI, Paolo;Di Giammatteo, Ugo
2022-01-01

Abstract

The Calibration Unit (CU) of MORFEO, the Multiconjugate adaptive Optics Relay For ELT Observations (formerly known as MAORY), is a complex optomechanical subsystem to project on the telescope NGS and LGS focal planes a large number of light sources at different wavelengths. These sources are needed to run calibration, verification and test procedures on MORFEO at the Extremely Large Telescope (ELT). This subsystem will play a critical role not only during operations, but also during the Assembly, Integration and Verification (AIV) phase in Italy, when it will be used in the Test Unit (TU) configuration, including a Deformable Mirror (DM), and in Chile. We present a general overview of the CU preliminary design, focusing on the reasons that led to the current optomechanical configuration and providing a more detailed description of the calibration sources, the light transmission chain and the electronics....
2022
9781510653511
9781510653528
File in questo prodotto:
File Dimensione Formato  
121855F (4).pdf

accesso aperto

Licenza: Non specificato
Dimensione 2.51 MB
Formato Adobe PDF
2.51 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/20.500.12386/36523
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact